I glanced at the name of the project on the title sheet but moved quickly into the guts of the drawings in order to get the design started. The design criteria for the fire sprinkler system was wrong. Sounds simple enough and, for the most part, it would have been except for one thing. FIRE SPRINKLER SYSTEM DESIGNER INSTALLDesign and install was in accordance with NFPA 13, Standard for the Installation of Sprinkler Systems. Other than that, it was business as usual. Nothing too dramatic, just a few items regarding fire department connection (FDC) locations and how their permit fees were determined. Having a long-standing relationship with this Authority Having Jurisdiction (AHJ), I was familiar with their currently adopted codes and standards as well as their amendments that were specific to their area. Knowing the area, I quickly identified the location and the associated jurisdiction I would be dealing with. So, there I was opening up a set of construction documents to begin a new fire sprinkler design for a new building being built. To get started with Fireline today, call us at 1-80, or visit our contact page.īe sure to “Like” and “Follow” the official Fireline page today on Google+, Facebook, Twitter, and LinkedIn.What’s the Building Owner Got to Do with It? Fireline offers the highest quality alarm systems to keep you safe from fires and carbon monoxide poisoning. In that case, buildings such as industrial parks and buildings with many tanks have deluge fire sprinkler systems installed.Īt Fireline, we offer an array of fire sprinkler systems and fire detection systems to keep your business safe. When flammable liquids are spread across a floor, deluge fire sprinklers are good to have. A deluge system has open nozzles that can be used when a hazard is present. These types of fire sprinkler systems also need a smoke or heat detector like the pre-action system. This fire sprinkler system is cost efficient and low maintenance. A type of building that uses the wet pipe system is a high-rise or office building with a few floors. This allows for a quick reaction to a fire and is the most common type of sprinkler installed in buildings. Wet pipe fire sprinklers constantly have water in them. Warehouses located in the north are a good example of what buildings should use dry pipe sprinklers. These fire sprinkler systems have a fast opening tool to get rid of the air and speed up the flow of water. This causes a minute delay in water discharge but is ideal for buildings with low temperatures so the pipes do not freeze. These places contain items of high value like electronics and goods damageable by water such as booksĭry pipe sprinklers are similar to pre-action systems as they use pressurized air in the pipe which exits before water escapes. Such buildings include libraries and data centers. The pre-action system is good for use in places where the sprinklers are only necessary when there is an actual fire so other items in the building do not get water damage from an accidental sprinkling. It helps greatly that the pre-action fire sprinkler can be set to prevent water from spouting in case of a false alarm or a mechanical failure. This type of system requires two triggers to start water flow. Pre-action fire sprinkler systems are filled with air and water is allowed to pass through when the smoke alarm or detector goes off. There are various types of fire sprinklers and below are descriptions of these so you know which one is best suited for your commercial building. Installing a sprinkler system is a good preventative measure to take. It is best to have protection in commercial buildings in case of fire or smoke.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |